5.7.2
Diagnostics via display elements
LEDs on the 3RA61 compact starter (direct starter)
Table 5- 15 Statuses of the LEDs on the 3RA61 compact starter (direct starter)
Compact starter status
Actuator
LED display
Mechanical display
ON I
A1/A2
RLT 0%
TRIP
Switched off (delivery
condition)
OFF
Control supply voltage
present with actuator set to
OFF
OFF
Ready
READY
Switched on
READY
Switched on following
malfunction
READY
Overload protection function
Overload tripped
READY
OR
1)
Short-circuit protection function
Short circuit tripped
TRIPPED
OR
1)
Malfunction (e.g. end of service life reached)
Malfunction tripped
TRIPPED
OR
1)
Ready following malfunction
READY
Switched on following
malfunction
READY
1)
Depends on whether control supply voltage is present at the same time
or whether no control supply voltage is
present
LED: Not illuminated
Mechanical display: No display
LED: Illuminated green
Mechanical display: White display
Содержание Sirius 3RA6
Страница 2: ......
Страница 14: ...Introduction SIRIUS 3RA6 compact starter 14 System Manual 09 2014 NEB560060102000 RS AA 006 ...
Страница 266: ...Technical data 9 5 8US busbar adapter SIRIUS 3RA6 compact starter 266 System Manual 09 2014 NEB560060102000 RS AA 006 ...
Страница 310: ...References B 1 References SIRIUS 3RA6 compact starter 310 System Manual 09 2014 NEB560060102000 RS AA 006 ...
Страница 314: ...Glossary SIRIUS 3RA6 compact starter 314 System Manual 09 2014 NEB560060102000 RS AA 006 ...
Страница 319: ......