Operation
8.6 Faults
1LE7 shaft heights 71 ... 315
88
Operating Instructions, 04/2022, A5E51689275A-AA
8.6.5
Faults on the separately driven fan
The following table shows the possible causes of and remedial measures for faults on forced-
ventilated motors.
Table 8- 4
Cooling system faults
↓ High temperature rise with load
Possible causes of faults
Remedial measures
X Wrong direction of rotation of the separately
driven fan
Check the electrical connections to the separately driven fan.
X separately driven fan is not running
Check the separately driven fan and its connections.
X Reduced air flow
Check the air ducts; clean the motor.