7 Drive Machine Data (SIMODRIVE Drive MD)
09.95
7.3.2 Drive MD (data description)
Value table:
Signal
number
Signal designation
Scaling
(LSB corresponds
to:)
0
Physical address
–
1
-
–
2
Current I
R
MD 1710
3
Current I
S
MD 1710
4
Current I
d
MD 1710
5
Current I
q
MD 1710
6
Current setpoint I
q
(limited after filter)
MD 1710
7
Current setpoint I
q
(before filter)
MD 1710
8
Motor speed actual value
MD 1711
9
Speed setpoint
MD 1711
10
Speed setpoint reference model
MD 1711
11
Torque setpoint (speed controller output)
MD 1713
12
Torque setpoint limit
MD 1713
13
Capacity utilization (m
set
/m
set,limit
)
8000H ˆ
=100%
14
Active power
0.01 kW
15
Rotor flux setpoint
MD 1712
16
Rotor flux actual value
MD 1712
17
Cross voltage U
q
MD 1709
18
Direct-axis voltage U
d
MD 1709
19
Current setpoint I
d
MD 1710
20
Motor temperature
0.1
o
C
21
DC link voltage
1 V
22
Zero mark signal, motor measuring system
–
23
Bero signal
–
24
Absolute actual speed value
MD 1711
25
Slip frequency setpoint
2000 x 2
––––––––––––––
800000H x 1s
-1
26
Rotor position (electrical)
MD 1714
27
Torque setpoint speed controller
MD 1713
28
Compensation torque
MD 1713
29
Command voltage Q injection
MD 1709
30
Command voltage D injection
1709
7–142
©