6 NC Machine Data (NC MD), NC Setting Data (NC SD)
01.99
6.6.1 General MD bits (general bits)
Bit 2
Bit 2 = 0,
Auxiliary function output during axis movement
Bit 2 = 1,
Auxiliary function output prior to travel
Active:
NC Stop
If an auxiliary function (M, S, T, H, D) is also programmed in a traversing block,
bit 2 can bring about the following two states:
Example:
N10
N15 M6 X100 LF
N20
(t)
N20
N15
N10
a a a
a a a
a a
a a
(V)
Velocity
Bit 2 = 0
M6
N10
(V)
M6
(t)
a a
a a
Bit 2 = 1
a a
a a
PLC cycle
Bit 1=1
If the bit is set, the internal WAIT mark synchronization is active.
Bit 1=0
WAIT mark synchronization via PLC
Active: NC STOP
Note:
Observe the internal WAIT MARK SYNCHRONIZATION DB 10-15 DL 15.8 interface signal as
from SW 6.3
Bit 0=1
No NC STOP in dwell block G04 S.../G14/G24. NC STOP is not active in
these blocks, but only at the end of the block.
Bit 0=0
NC STOP is immediately active; the dwell time and thus the block are aborted
completely. The next block is started with NC START.
Active: NC STOP
Note
A dwell time with G04 x..., G04 F... is always aborted by NC STOP.
6–90
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)
Содержание SIMODRIVE 611-D
Страница 2: ......