SINUMERIK 840C (IA)
2.5
Memory configuration (as from SW 3)
Standard values
for DRAM
1 MB Part prog.
704 kB Part prog.
512 kB
UMS
256 kB IKA
16 000 points
256 kB
UMS
64 kB IKA
4 000 points
240 kB
Block buffer
0 kB
Meas. value mem.
0 kB
FDD/MSD
704 kB Part prog.
256 kB
UMS
64 kB IKA
4 000 points
240 kB
Block buffer
0 kB
Meas. value mem.
0 kB
FDD/MSD
Softw. 3
Softw. 4
4 MB DRAM
Softw. 4
8 MB DRAM
2 MB free (SW 4.1–4.3)
3.896 MB free (as from
SW 4.4)
or see below (maximum)
Setting ranges
for DRAM
Note: The ranges cannot be set in software version 3.
SW 4.1 – 4.3
As from SW 4.4
As from SW 5.4
Part programs
32 kB to
2 760 kB
32 kB to
4 920 kB
UMS
0
to
1 024 kB
0
to
2 760 kB
1)
IKA
0
to
1 024 kB
0
to
65 535 points
0
to
1 024 kB
0
to
65 535 points
FDD/MSD
0
or
194/388 kB
0
or
194/388 kB
Block buffer
0
to
2 760 kB
0
to
approx. 1 800
buffers
0
to
5 026 kB
0
to
approx. 3 450
buffers
Measured value
memory
0
to
2 760 kB
0
to
700 000
meas. values
0
to
2 760 kB
0
to
700 000
meas. values
Number of real axes
Axes 15 to 30
16 kB
each
Data for extended
overstore
Axes 1 to 6
49 kB
each
Number of measured
value buffers
Axes 1 to 30
4 byte
each
Maximum
1 264 kB with 4 MB DRAM
3 264 kB with 8 MB DRAM SW 4.1–4.3
5 160 kB with 8 MB DRAM as from SW 4.4
Note as from SW 4:
For UMS at least the memory capacity specified by the WS 800 configuration
station must be entered (not the length of the UMS file transferred).
2 General Reset and Standard Start-Up
2.5 Memory configuration (as from SW 3)
04.96
1) WS 800 can up to 1024