01.99
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.9.1 MDs for collision monitoring
Protection dimensions in 3 coordinates not equal to 0:
Three-dimensional monitoring
Definition:
Two-dimensional protection zone to be mutually monitored for collision must be in the same
plane.
Assigned MCS (as from SW 6)
3840*
Default value
Lower input limit
Upper input limit
Units
0
0
3
–
Active on
POWER ON
with *= protection zone index:
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31
A machine coordinate system (MCS) must be assigned to each protection zone. These
assignments are made in the protection-zone-specific machine data:
Value range:
0/1 = 1st machine coordinate system
2
= 2nd machine coordinate system
3
= 3rd machine coordinate system
4
= 4th machine coordinate system
Note:
For more detailed information please see Functional Description.
3876*
Res.
Res.
Res.
Res.
Res.
Res.
Additive
protection
zone
adjustment
(as from
SW 6.3)
Protection
zone exists
MD No.
Bit No.
7
6
5
4
3
2
1
0
with *=protection zone index:
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31
Monitoring of a defined protection zone can be activated with this MD.
Bit 0
Bit 0=0
Protection zone does not exist
Bit 0=1
Protection zone exists
Active: POWER ON
Bit 1
Bit 1=0
Additive protection zone adjustment via setting data inactive
Bit 1=1
Additive protection zone adjustment via setting data active
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50