Technical specifications
A.2 S7-200 SMART CPUs
S7-200 SMART
698
System Manual, V2.3, 07/2017, A5E03822230-AF
Technical data
CPU ST30 DC/DC/DC
CPU SR30 AC/DC/Relay
CPU CR30s AC/DC/Relay
Isolation (input power to
logic)
--
1500 V AC
1500 V AC
Ground leakage, AC line
to functional earth
--
0.5 mA max.
0.5 mA max.
Hold up time
(loss of power)
20 ms at 24 V DC
30 ms at 120 V AC
200 ms at 240 V AC
30 ms at 120 V AC
200 ms at 240 V AC
Internal fuse,
not user replaceable
3 A, 250 V, slow blow
3 A, 250 V, slow blow
3 A, 250 V, slow blow
Table A- 29 Sensor power
Technical data
CPU ST30 DC/DC/DC
CPU SR30 AC/DC/Relay
CPU CR30s AC/DC/Relay
Voltage range
20.4 to 28.8 V DC
20.4 to 28.8 V DC
Not available
Output current rating
(max.)
300 mA
(short circuit protected)
300 mA
(short circuit protected)
Not available
Maximum ripple noise
(<10 MHz)
< 1 V peak to peak
< 1 V peak to peak
Not available
Isolation (CPU logic to
sensor power)
Not isolated
Not isolated
Not available
A.2.2.2
Digital inputs and outputs
Table A- 30 Digital inputs
Technical data
CPU ST30 DC/DC/DC
CPU SR30 AC/DC/Relay
CPU CR30s AC/DC/Relay
Number of inputs
18
18
18
Type
Sink/Source (IEC Type 1 sink,
except I0.0 to I0.3, I0.6 to
I0.7)
Sink/Source (IEC Type 1
sink)
Sink/Source (IEC Type 1
sink)
Rated voltage
24 V DC at 4 mA, nominal
24 V DC at 4 mA, nominal
24 V DC at 4 mA, nominal
Continuous permissible
voltage
30 V DC, max
30 V DC, max.
30 V DC, max.
Surge voltage
35 V DC for 0.5 sec.
35 V DC for 0.5 sec.
35 V DC for 0.5 sec.
Logic 1 signal (min.)
I0.0 to I0.3, I0.6 to I0.7: 4 V
DC at 8 mA
Other inputs: 15 V DC at 2.5
mA
15 V DC at 2.5 mA
15 V DC at 2.5 mA
Logic 0 signal (max.)
I0.0 to I0.3, I0.6 to I0.7: 1 V
DC at 1 mA
Other inputs: 5 V DC at 1 mA
5 V DC at 1 mA
5 V DC at 1 mA
Isolation (field side to
logic)
500 V AC for 1 minute
500 V AC for 1 minute
500 V AC for 1 minute
Isolation groups
1
1
1
Содержание SIMATIC S7-200
Страница 30: ...Product overview 1 7 Programming software S7 200 SMART 30 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 267: ...Program instructions 7 6 Counters S7 200 SMART System Manual V2 3 07 2017 A5E03822230 AF 267 HSC modes 3 and 4 ...
Страница 394: ...Program instructions 7 18 Subroutine S7 200 SMART 394 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 425: ...Communication 8 5 PROFIBUS S7 200 SMART System Manual V2 3 07 2017 A5E03822230 AF 425 ...
Страница 786: ...Technical specifications A 11 S7 200 SMART cables S7 200 SMART 786 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 798: ...Error codes C 4 PLC fatal error codes S7 200 SMART 798 System Manual V2 3 07 2017 A5E03822230 AF ...
Страница 848: ...Ordering information F 6 Human Machine Interface devices S7 200 SMART 848 System Manual V2 3 07 2017 A5E03822230 AF ...