ET 200U Distributed I/O Station
EWA 4NEB 812 6087-02b
Figures
5-1
ET 200U(DP Standard): CONFIGURING Screen (1)
5-4
. . . . . . . . . . . . . . . . . .
5-2
ET 200U(DP Standard): CONFIGURING screen (2)
5-5
. . . . . . . . . . . . . . . . . .
5-3
ET 200U(DP Standard): CONFIGURING Screen (3)
5-6
. . . . . . . . . . . . . . . . .
5-4
Example of Process I/O Image with ET 200
5-7
. . . . . . . . . . . . . . . . . . . . . . . . .
5-5
Structure of Parameterization Frame
5-16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6
Location of the Bank of Switches for Setting the Station Number
5-21
. . . . . . .
5-7
SYSTEM START–UP/TEST: MODULE SELECTION Screen
5-24
. . . . . . . . . . .
5-8
SYSTEM START–UP/TEST: STATUS/CONTROL Screen
5-25
. . . . . . . . . . . . .
5-9
Fault LEDs on the ET 200U Interface Module
5-29
. . . . . . . . . . . . . . . . . . . . . . .
5-10
DIAGNOSTICS: OVERVIEW Screen
5-30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-11
INDIVIDUAL DIAGNOSTICS Screen
5-31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-12
Structure of the Diagnostics Word after Request of the Station Status
(Station Status 1 and Station Status 2)
5-35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-13
Structure of the Diagnost. Word after Request of the Station Status
(Station Status 3 and Master Address)
5-35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-14
Structure of the Diagnostics Word after Request of the Manufacturer
Identification
5-36
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-15
Structure of the Diagnostics Word after Request of Station Diagnostics
5-37
.
5-16
Structure of the Diagnostics Word after Request of Module Diagnostics
(Header and Slots 0 to 7)
5-38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-17
Structure of the Diagnostics Word after Request of Module Diagnostics
(Slots 8 to 15 and 16 to 23)
5-39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-18
Structure of the Diagnostics Word after Request of Module Diagnostics
(Slots 24 to 31)
5-39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tables
5-1
Names of the Type Files for the ET 200U
5-10
. . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2
Address IDs for the Modules in an ET 200U(DP Standard) Station
5-10
. . . . . .
5-3
Address IDs for the Modules in an ET 200U(DP Standard) Station
5-11
. . . . . .
5-4
Address IDs for the Modules in an ET 200U(DP Standard) Station
5-12
. . . . . .
5-5
Address IDs for the Modules in an ET 200U(DP Standard)
5-13
. . . . . . . . . . . .
5-6
Explanation of Parameters in the DP–IDENTIFIER Field
5-14
. . . . . . . . . . . . .
5-7
Meaning of the Parameters in the Parameterization Frame
5-16
. . . . . . . . . . . .
5-8
Function of Switch 8
5-22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9
Resetting Outputs with Load Circuit Turned On
5-27
. . . . . . . . . . . . . . . . . . . . . .
5-10
LED Fault Messages on ET 200U Interface Module
5-29
. . . . . . . . . . . . . . . . . .
5-11
Diagnostics with STEP 5
5-32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-12
Structure of Station Diagnostics and Module Diagnostics
5-33
. . . . . . . . . . . . . .
ET 200U(DP Standard): Address Assignment, Starting Up, Diagnosing Faults