5-24
ET 200U Distributed I/O Station
EWA 4NEB 812 6087–02b
5.2.3 Using the SYSTEM START–UP/TEST Screen for an ET 200U(DP
Standard) Slave Station
For starting up an ET 200U slave station, COM ET 200 provides two screens.
Select one slot in the SYSTEM START–UP/TEST: MODULE SELECTION
screen. Then call up the SYSTEM START–UP/TEST: STATUS/CONTROL
screen.
Proceed as follows:
1. Using the cursor control keys and <F5> (SELECT), select one slot (one
module) whose input data you want to evaluate or whose outputs you
want to force.
Result: The selected module is marked with an asterisk “*”. Pressing
<F5> (SELECT) a second time cancels the selection.
SELECT
ENTER
EXIT
F2
F3
F4
F5
F6
F7
F8
F1
Station number: 4
Program file selected: TEST@@ET.200
SIMATIC S5 / COM ET 200
SYSTEM START–UP / TEST: MODULE SELECTION
Station type: ET 200U–DP
Station name:
PRESS
Configuration:
0.
016
1.
2.
3.*
4.
5.
6.
7.
032
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
097
243
243
Figure 5-7 SYSTEM START–UP/TEST: MODULE SELECTION Screen
ET 200U(DP Standard): Address Assignm.,Starting–Up, Diagnosing Faults Using COM ET 200