Technical data
13.1 Technical specifications RF185C, RF186C, RF188C
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
180
Operating Instructions, 04/2020, C79000-G8976-C512-03
6GT2002-0JEx0
Electrical data
Supply voltage
2)
•
Rated value
•
24 VDC
•
Permitted range
•
20 to 30 VDC
Current consumption without reader
Typ. 130 mA
Current draw via reader interfaces
max. 800 mA each, at 24 V DC
Mechanical data
Dimensions (W × H × D)
60 × 165 × 45 mm
Weight
Approx. 260 g
Environmental conditions
Ambient temperature
•
During operation
•
-25 ... +55 °C
•
During transportation and storage
•
-40 ... +70 °C
Degree of protection
IP67
Oscillation, vibration in operation
(according to IEC 60068-2-27)
0.75 mm (10 … 58 Hz)
4 g (58 … 150 Hz)
Shock resistance, shock in operation
(according to IEC 60068-2-6)
30 g
MTBF (at 40°C)
70 years
Approvals
•
CE
•
cULus (file E85972)
•
FCC Code of Federal Regulations,
CFR 47, Part 15,
Sections 15.107 and 15.109 (Class A)
•
PNO-certified according to Conformance
Class B
1)
Depending on the connected reader.
2)
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to
IEC 61140) 24 V DC supply: Safety (electrical) isolation of low voltage (SELV/PELV acc. to
IEC 61140)