Service and maintenance
12.2 Error messages
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
164
Operating Instructions, 04/2020, C79000-G8976-C512-03
AutoId
status
OPC UA
status
AutoId
text
Error description
1
good
MISC_ERROR_
TOTAL
Enabling write protection on the transponder has failed.
1
good
MISC_ERROR_
TOTAL
The "Kill" command failed.
3
good
PERMISSON_
ERROR
The transponder is read/write-protected.
4
good
PASSWORD_
ERROR
The transponder password is incorrect. Access is denied.
5
Bad
Invalid
Argument /
good
REGION_NOT_
FOUND_ERROR
All commands:
A parameter of an OPC UA command has an invalid value.
"ReadTag"/"WriteTag" command:
The addressed memory area is not available in the current
transponder.
7
good
OUT_OF_RANGE_
ERROR
Address error
The address range of the transponder has been exceeded.
Possible causes:
•
Start address of the command start has been incorrectly
set.
•
Wrong transponder type
•
The area to be written to is write-protected.
7
good
OUT_OF_
RANGE_ERROR
The requested data is not available.
8
good
NO_
IDENTIFIER
There is no transponder with the required EPC ID/UID in the
transmission window or there is no transponder at all in the
antenna field.
9
good
MULTIPLE_
IDENTIFIERS
More transponders are located in the transmission window than
can be processed at the same time by the reader.
9
good
MULTIPLE_
IDENTIFIERS
There is more than one transponder in the transmission win-
dow.
10
good
READ_
ERROR
Read access to the transponder has failed.
14
good
WRITE_
ERROR
Write access to the transponder has failed.
14
good
WRITE_
ERROR
Writing the EPC ID/UID on the transponder has failed.
15
good
NOT_SUPPORTED_
BY_DEVICE
Unknown command
An uninterpretable XML command was sent to the reader or the
Ident profile sends an uninterpretable command to the reader.
Possible causes:
•
The "AdvancedCmd" block was supplied with an incorrect
"CMD".
•
The "CMD" input of the "AdvancedCmd" block was overwrit-
ten.
17
good
DEVICE_NOT_
READY
The specified read point is not active because no antenna was
assigned to it.