Configuring
6.2 Configuration via PROFINET IO
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
54
Operating Instructions, 04/2020, C79000-G8976-C512-03
"Web Based Management" parameter group
You can start Web Based Management in this parameter group.
Table 6- 1
Parameters of the "Web Based Management" parameter group
Parameter
Description
Web Based Manage-
ment
Start Web Based Management of the communication module.
Web Based Management (WBM) offers extensive functions for configuring the communication
module.
Note: WBM can only be started when the IP address stored in the project has been assigned to
the communication module. This means that the device name must have been assigned and the
TIA configuration must be loaded into the SIMATIC controller.
"Configuration management" parameter group
You can load or save configuration data in this parameter group.
Table 6- 2
Parameters of the "Configuration management" parameter group
Parameter
Description
User name
1)
User name of a user created on the communication module
Note that the user must have the required rights.
Password
1)
Enter the password for the user
Load configuration to
device
Load configuration data from the STEP 7 project into the communication module.
Save configuration in
project
Save configuration data of the communication module in the current STEP 7 project.
1)
User name and password must only be entered when the user management of the WBM is enabled.
Requirement
The following requirements must be met so that configuration data can be loaded or saved:
●
The "PROFINET interface [X1]" entry contains the correct IP address of the
communication module.
●
The specified user has the required rights to perform the download/upload.
Note
User name and password only necessary if user management is enabled
The "User name" and "Password" text boxes only need to be completed if the user
management of the CM in the WBM is enabled.