![Siemens SIMATIC RF185C Скачать руководство пользователя страница 160](http://html.mh-extra.com/html/siemens/simatic-rf185c/simatic-rf185c_operating-instructions-manual_382133160.webp)
Service and maintenance
12.2 Error messages
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
160
Operating Instructions, 04/2020, C79000-G8976-C512-03
"ER"
LED
Block (hex)
Error description
--
0xE5FE0600 Invalid data block length (DBL) on the reader/communication module
--
0xE5FE0700 Invalid data block length (DBL) in the Ident profile
--
0xE5FE0800 The previous command is still active or the buffer is full.
A new command was sent to the reader or communication module although the last command is
still active.
•
The active command can only be aborted with "INIT".
•
Before a new command can be started, "DONE bit = 1" must be set (exception "INIT").
•
Two Ident profile calls were assigned the same "HW_ID", "CM_CHANNEL" and "LADDR"
parameter settings.
•
Two Ident profile calls are using the same pointer.
•
After eliminating the error, execute the "INIT" command.
•
When working with command repetition (e.g., fixed code transponder), no data is being
fetched from the transponder. The data buffer on the reader/communication module has
overflowed. Transponder data has been lost.
--
0xE5FE0900 The reader or the communication module runs a hardware reset ("INIT_ACTIVE" set to "1"). The
Ident profile expects an "INIT" (bit 15 in the cyclic control word).
--
0xE5FE0A00 The "CMD" command code and the relevant acknowledgment do not match. This can be a soft-
ware error or synchronization error that cannot occur in normal operation.
--
0xE5FE0B00 Incorrect sequence of acknowledgment frames (TDB / DBN)
--
0xE5FE0C00 Synchronization error (incorrect increment of "AC_H / AC_L" and "CC_H / CC_L" in the cyclic
control word). "INIT" had to be executed.
3x
0xE5FE8100 Communication error between reader and communication module
Access denied
3x
0xE5FE8200 Communication error between reader and communication module
Resource is occupied
3x
0xE5FE8300 Communication error between reader and communication module
Functional error of the reader interface
3x
0xE5FE8400 Communication error between reader and communication module
Other faults/errors
4x
0xE6FE0100 Unknown command
An uninterpretable XML command was sent to the reader or the Ident profile sends an uninter-
pretable command to the reader.
Possible causes:
•
The "AdvancedCmd" block was supplied with an incorrect "CMD".
•
The "CMD" input of the "AdvancedCmd" block was overwritten.
4x
0xE6FE0200 Invalid command index (CI)