Configuring Extension Unit PROFINET and PROFIsafe
4.6 Configuring standard operator controls
Extension Units KPxx
Operating Instructions, 05/2019, A5E43600360-AC
71
Properties of the standard operator controls
Operator control
Input (contact)
Output (LED)
Indicator light
1
-
1 bit
•
"0": LED off
•
"1": LED on
Illuminated pushbutton
1
1 NC contact
1 bit (7.0)
•
"0": Pushbutton is not pressed
•
"1": Pushbutton is pressed
1 bit
•
"0": LED off
•
"1": LED on
Illuminated pushbutton
1
1 NC contact, 1 NO contact
2 bits (7.1|7.0)
•
"10": Pushbutton is not pressed
•
"01": Pushbutton is pressed
1 bit
•
"0": LED off
•
"1": LED on
Selector switch
2 bits (7.1|7.0)
2
•
"00": Position "Center"
•
"01": Position "Right"
•
"10": Position "Left"
1 bit
•
"0": LED off
•
"1": LED on
Keyswitch
2 bits (7.1|7.0)
2
•
"00": Position "Center"
•
"10": Position "Right"
•
"01": Position "Left"
-
1
The color of the lens assembly for representation in the device view (TIA Portal) can be config-
ured.
2
The positions "Center", "Right" and "Left" refer to the front view of the operator control or the
Extension Unit.
The figure below shows the correlation between switch settings and the associated input
bits.