Introduction to the SINAUT ST7 system
2.5 Mobile wireless components
SINAUT ST7 Station control system - System Manual
System Manual, 05/2007, C79000-G8976-C178-06
71
MD740-1
Packet authentication
MD5, SHA-1
Miscellaneous
DynDNS,
NAT-T,
Dead Peer Detection (DPD)
Firewall
•
Stateful Packet Inspection
•
Anti-Spoofing
•
Network Address Translation (NAT) /
IP-Masquerading)
•
Port forwarding
•
Yes
•
Yes
•
Yes
•
Yes
Other features
DNS cache,
DHCP server,
NTP,
remote logging
Yes
Yes
Yes
Yes
Configuration
with standard Web browser
Tests, approvals
•
CE
•
R&TTE (GSM)
•
GSM/GPRS
•
EMC / ESD
•
Electrical safety
•
ATEX
•
FM
•
UL
•
Yes
•
Yes
•
with GCF approval
•
EN 55024, EN 55022 class A,
EN 61000-6-2
•
EN 60950
•
III 3G EEx nA II T4,
Ta = 20 °C...50 °C
KEMA: 03 ATEX 1229 X
•
CLI, DIV2, GP. A,B,C,D T4
Ta = 20 °C...50 °C
•
Yes
National approvals
For up-to-date information, check the Internet at
http:/www.siemens.com/simatic-net/ik-info