Product properties
3.10 SCALANCE X124
SCALANCE X-100
Operating Instructions, 04, A2B00060666D
35
3.10.2
SCALANCE X124 TP ports
Connector pinout
On the SCALANCE X124, the TP ports are implemented as RJ-45 sockets with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Figure 3-14 RJ-45 jack
Table 3- 9
Pin assignment of the RJ-45 jack
Pin number
Assignment
Pin 8
n. c.
Pin 7
n. c.
Pin 6
TD-
Pin 5
n. c.
Pin 4
n. c.
Pin 3
TD+
Pin 2
RD-
Pin 1
RD+
NOTICE
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45
TP port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of up to 100 m is
permitted between two devices depending on the cable type.
Содержание SIMATIC NET SCALANCE X-100 Series
Страница 40: ...Product properties 3 12 Displays SCALANCE X 100 40 Operating Instructions 04 A2B00060666D ...
Страница 54: ...Approvals and markings SCALANCE X 100 54 Operating Instructions 04 A2B00060666D ...
Страница 60: ...Technical specifications 6 1 Technical specifications SCALANCE X 100 60 Operating Instructions 04 A2B00060666D ...
Страница 62: ...References SCALANCE X 100 62 Operating Instructions 04 A2B00060666D ...
Страница 68: ...Dimension drawings 8 1 Dimension Drawing SCALANCE X 100 68 Operating Instructions 04 A2B00060666D ...
Страница 72: ...Glossary SCALANCE X 100 72 Operating Instructions 04 A2B00060666D ...
Страница 74: ...Index SCALANCE X 100 74 Operating Instructions 04 A2B00060666D U UL approval 6 ...