Technical specifications
6.1 Technical specifications
SCALANCE X-100
Operating Instructions, 04, A2B00060666D
59
Note
The number of SCALANCE X Industrial Ethernet Switches connected in a line influences the
frame propagation time.
When a frame passes through devices of the SCALANCE X-100 product line, it is delayed by
the store and forward function of the switch
•
With a 64 byte frame length by approx. 10 microseconds (at 100 Mbps)
•
With a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps)
This means that the more devices of the SCALANCE X-100 product line, the frame passes
through, the longer the frame delay.