Installation, connecting up, sources of problems
4.1 Assembly
SCALANCE X-100
Operating Instructions, 04, A2B00060666D
43
Uninstalling
To remove the Industrial Ethernet switches of the SCALANCE X-100 product line from the
DIN rail:
1.
First disconnect all connected cables.
2.
Use a screwdriver to release the lower DIN rail catch of the device and pull the lower part
of the device away from the rail.
Figure 4-2
SCALANCE X-100 removing from a DIN rail (35 mm)
4.1.2
Installation on a standard rail
Installation on a SIMATIC S7-300 standard rail
1.
Place the upper guide at the top of the SCALANCE housing in the S7 standard rail.
2.
Screw the Industrial Ethernet switches of the SCALANCE X-100 product line to the
underside of the S7 standard rail.
3.
Fit the connectors for the power supply.
4.
Fit the connectors for the signaling contact.
5.
Insert the terminal blocks into the sockets on the device.
Figure 4-3
SCALANCE X-100 installation on a SIMATIC S7-300 standard rail
Содержание SIMATIC NET SCALANCE X-100 Series
Страница 40: ...Product properties 3 12 Displays SCALANCE X 100 40 Operating Instructions 04 A2B00060666D ...
Страница 54: ...Approvals and markings SCALANCE X 100 54 Operating Instructions 04 A2B00060666D ...
Страница 60: ...Technical specifications 6 1 Technical specifications SCALANCE X 100 60 Operating Instructions 04 A2B00060666D ...
Страница 62: ...References SCALANCE X 100 62 Operating Instructions 04 A2B00060666D ...
Страница 68: ...Dimension drawings 8 1 Dimension Drawing SCALANCE X 100 68 Operating Instructions 04 A2B00060666D ...
Страница 72: ...Glossary SCALANCE X 100 72 Operating Instructions 04 A2B00060666D ...
Страница 74: ...Index SCALANCE X 100 74 Operating Instructions 04 A2B00060666D U UL approval 6 ...