Introduction
SCALANCE X-100
6
Operating Instructions, 04, A2B00060666D
Standards and approvals
The Industrial Ethernet switches of the SCALANCE X-100 product line meet the
requirements for the CE, UL, C-Tick, FM and ATEX marks. You will find detailed information
in the section "Approvals and Markings" in this commissioning manual in the "Approvals"
table.
Note
The specified approvals apply only when the corresponding mark is printed on the product.
What is possible?
The devices of the SCALANCE X100 product line allow the cost-effective installation of
Industrial Ethernet bus and star structures with switching functionality. The
SCALANCE X104-2, SCALANCE X106-1 and SCALANCE X112-2 also allow the switchover
between electrical/optical media. SCALANCE X devices with the suffix PoE also allow the
supply of power to end devices over Ethernet cables with Power-over-Ethernet complying
with 802.3af.
Note
It is not possible to use devices of the SCALANCE X-100 product line in a redundant ring
because they do not support redundancy.
Note
If devices of the SCALANCE X-100 product line are supplied over long 24 V power supply
lines or networks, measures are necessary to prevent interference by strong electromagnetic
pulses on the supply lines. These can result, for example, as a result of lightning or large
inductive loads.
One of the tests to attest the immunity of devices of the SCALANCE X-100 product line to
electromagnetic interference was the "surge immunity test" according to EN61000-4-5. This
test requires overvoltage protection for the power supply lines. A suitable device is, for
example, the Dehn Blitzductor VT AD 24 V type no. 918 402 or comparable protective
element.
Manufacturer:
DEHN+SÖHNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D-92306 Neumarkt,
Germany
WARNING
When used under hazardous conditions (zone 2), a switch of the SCALANCE X-100
product line must be installed in an enclosure.
To comply with ATEX95 (EN 60079-15), this enclosure must meet the requirements of at
least IP54 in compliance with EN 60529.
WARNING – EXPLOSION HAZARD: DO NOT DISCONNECT EQUIPMENT WHEN A
FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT.
Содержание SIMATIC NET SCALANCE X-100 Series
Страница 40: ...Product properties 3 12 Displays SCALANCE X 100 40 Operating Instructions 04 A2B00060666D ...
Страница 54: ...Approvals and markings SCALANCE X 100 54 Operating Instructions 04 A2B00060666D ...
Страница 60: ...Technical specifications 6 1 Technical specifications SCALANCE X 100 60 Operating Instructions 04 A2B00060666D ...
Страница 62: ...References SCALANCE X 100 62 Operating Instructions 04 A2B00060666D ...
Страница 68: ...Dimension drawings 8 1 Dimension Drawing SCALANCE X 100 68 Operating Instructions 04 A2B00060666D ...
Страница 72: ...Glossary SCALANCE X 100 72 Operating Instructions 04 A2B00060666D ...
Страница 74: ...Index SCALANCE X 100 74 Operating Instructions 04 A2B00060666D U UL approval 6 ...