
Image processing
3.4 Options for image acquisition and image processing
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
87
Note
Duration of image acquisition interval and decoding time
Note that the image acquisition interval (b) is always the same length as the decoding time
limit (c).
Number of acquired images = {(Timeout/Acquisition interval) - 1}
Auto-trigger edge-triggered with timeout
In the following example, images are acquired with a rising edge of the trigger until an image
can be recognized and decoded, or until the timeout stops image acquisition.
①
Trigger initiates the operation.
②
Trigger signal is ignored.
a
Image acquisition time
b
Image acquisition interval
c
Limit of the decoding time
No code found.
Code found.
Figure 3-21 Time diagram: Auto-trigger with the "edge-triggered start/stop" option
Note
Duration of image acquisition interval and decoding time
Note that the image acquisition interval (b) is always the same length as the decoding time
limit (c).
Number of acquired images = {(Timeout/Acquisition interval) - 1}
Содержание SIMATIC MV500
Страница 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Страница 16: ......
Страница 28: ......
Страница 32: ......
Страница 92: ......
Страница 114: ......
Страница 148: ......
Страница 244: ......
Страница 254: ......
Страница 260: ......
Страница 292: ......
Страница 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...