Image processing
3.2 Code verification
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
69
3.2.9.2
Standard report for ISO/IEC 15415
Table 3- 11 Output parameters: ISO/IEC 15415
Field name (String input)
Value
Verification type (Qt)
2
If the exposure settings do not comply with the
standard: C
Evaluation (Qs)
3 (Good), 2 (Fair), 1 (Poor)
Overall grade (Q0)
4 ... 0
Reference decode grade (Q7)
4 ... 0
Contrast grade (Q1)
4 ... 0
Contrast (q1)
0 ... 100
Axial non-uniformity grade (Q2)
4 ... 0
Axial non-uniformity (q2)
0.00 ... 1.00
Grid non-uniformity grade (Q3)
4 ... 0
Grid non-uniformity (q3)
0.00 ... 1.00
Unused error correction grade (Q4)
4 ... 0
Unused error correction (q4)
0.00 ... 1.00
L/F border violation grade (Q5)
4 ... 0
Modulation grade (Q6)
4 ... 0
Print growth X (q9)
-100 ... 100
Print growth Y (q9)
-100 ... 100
Cell size (q10)
0 ... 99.9 mil
Aperture (q12)
0, 4 ... 20 mils
(0 corresponds to automatic)
ECCLevel (q14)
200
Height (q15)
0 ... 9.99 inch
Width (q16)
0 ... 9.99 inch
Angle (q17)
0 ... 360°