Process interfacing via an automation system (PLC, PC)
9.1 Integration via PROFINET IO without CM
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
153
9.
In the shortcut menu, select the menu command "Assign device name".
Reaction: The "Assign PROFINET device name" window opens.
Figure 9-2
STEP 7 TIA Portal: Assigning PROFINET device names
10.Select the connection type in the "Online access" in the "Type of the PG/PC interface" drop-
down list.
11.In the "PG/PC interface" drop-down list in the "Online access" area, select the network
adapter via which the optical reader is connected to the PC.
12.Click the "Update list" button to display all reachable devices in the network.
13.Select the required device from the list.
14.Now click the "Assign name" button to assign the PROFINET device name to the optical
reader.
Result: The reader is assigned the configured PROFINET device name from the project.
Alternatively, you can use SINEC PNI or the WBM ("Settings > Communication > Interfaces >
PROFINET IO > Device name") to assign the reader a unique PROFINET device name.