Process interfacing via an automation system (PLC, PC)
9.5 Controlling the I/O interface "DI/DQ"
SIMATIC MV500
196
Operating Instructions, 03/2021, C79000-G8976-C494-05
9.5
Controlling the I/O interface "DI/DQ"
Control signals
Note
Range of functions depends on the settings in WBM
Note that the control of the reader via the digital inputs/outputs depends on the settings in
the menu "Settings > Communication > Digital I/O" of the WBM.
Table 9- 51 Assignment of control bytes (input signals)
Name
Description
TRG
Trigger
Processing starts on a positive edge.
The optical reader has two freely assignable digital outputs. The following table provides an
overview of the possible output signals.
Table 9- 52 Assignment of status byte (output signals)
Name
Description
IN_OP
In operation
•
0: Error message is displayed.
•
1: Optical reader functioning, no error
TRD
Trained
•
In run:
–
0: Selected program is not saved.
–
1: Selected program has been saved.
•
With Save program (TRN = 1):
–
0: Save program active.
–
1: Acknowledgment signal (RDY = 0)
RDY
Ready:
•
0: Startup of the optical reader or optical reader in STOP
•
1: Optical reader in run
READ
Processing result
Code was localized and decoded.
MATCH
Processing result
Code matches the trained code.
N_OK
Code was not legible.
Содержание SIMATIC MV500
Страница 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Страница 16: ......
Страница 28: ......
Страница 32: ......
Страница 92: ......
Страница 114: ......
Страница 148: ......
Страница 244: ......
Страница 254: ......
Страница 260: ......
Страница 292: ......
Страница 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...