Process interfacing via an automation system (PLC, PC)
9.9 SNMP
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
215
Scope of performance of the optical reader as an SNMP agent
The optical reader supports data query in the following SNMP versions:
•
SNMPv1 (standard)
For the optical reader, only SNMP variables from the following MIBs are supported:
•
LLDP-MIB
•
Standard MIB II (according to RFC1213)
–
Group "System"
–
Group "Interfaces"
Write access is permitted only for the following MIB objects of the "System" group:
•
sysContact
•
sysLocation
•
sysName
For all other MIB objects / MIB object groups, only read access is possible for security reasons.
Traps are not supported by the optical reader.
Access permissions using community names
The optical reader uses the following community strings to control the access rights to the
SNMP agent:
Table 9- 62 Access rights in the SNMP agent
Type of access
Default community string
Read access
public
Read and write access
private
NOTICE
Change community string
Note that the default community string is generally known and therefore does not provide
effective protection.
To make sure that no unauthorized persons can access the device, we recommend that you
change the community string when the device is first set up.
Содержание SIMATIC MV500
Страница 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Страница 16: ......
Страница 28: ......
Страница 32: ......
Страница 92: ......
Страница 114: ......
Страница 148: ......
Страница 244: ......
Страница 254: ......
Страница 260: ......
Страница 292: ......
Страница 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...