Wiring
4-16
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Power from the drive unit
Figure 4-8 shows examples of how to power the standby signal from the drive unit.
FM 353
RM_P
RM_N
L+
M
19
9
10
20
X1
RM_P
RM_N
L+
M
19
9
10
20
X1
M
M
P24
P24
Power section
Actuation, current-sourcing
Actuation, current-sinking
Fig. 4-8
Actuation of the input controller message, power supply from the
drive unit
4 digital outputs (DQ1...4)
All outputs have equal priority. The switching function is allocated to the output
number in machine data (see
These four outputs are intended for wiring of application-specific signals.
Possible uses include:
S
Position reached and stopped
S
Switching function M command
S
Forward/backward rotation
See Section 5.3.1 for further applications.
Note
Make sure that the cable length between the digital outputs and the load does not
exceed a permissible max. length of 30 m.
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...