Programming the Technological Functions
6-36
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Processing write requests
Before Write requests can be processed, the data area associated with the Write
request must first be initialized with the relevant values and the appropriate operat-
ing mode.
A Write request is initiated by setting the relevant job request number.
The following abbreviations are used in the Table below to indicate the adjacent
operating mode:
Operating mode:
T
−
Jogging mode
STE
−
Control mode
REF
−
Approach to reference point
SM
−
Incremental mode (relative)
MDI
−
MDI (Manual Data Input)
A/AE
−
Automatic mode / Automatic single block
The following Write requests are available:
Operating Mode
System Data
Write
Request
Data
T
STE REF SM MDI A/AE
See
Sect.
Speed levels 1, 2
DBX38.0 DBB160...167
V
d
d
V
d
d
Frequency levels 1, 2
DBX38.1 DBB168...175
d
V
d
d
d
d
Setpoint for incremental di-
mension
DBX38.2 DBB156...159
d
d
d
V
d
d
MDI block
DBX38.3 DBB176...195
d
d
d
d
V
d
MDI block, on-the-fly
DBX38.4 DBB222...241
−
−
−
−
x
−
Reserved
DBX38.5
Set reference point
DBX38.6 DBB152...155
x
x
x
x
x
−
Set actual value
DBX38.7 DBB144...147
x
x
−
x
x
x
Set on-the-fly actual value
DBX39.0 DBB148...151
x
x
−
x
x
−
Zero offset
DBX39.1 DBB140...143
x
x
−
x
x
x
Reserved
DBX39.2
x
x
x
x
x
x
Modify parameters/data
DBX39.3 DBB196...219
x
x
x
x
x
x
Digital outputs
DBX39.4 DBB220...221
x
x
x
x
x
x
Program selection
DBX39.5 DBB242...245
−
−
−
−
−
V
Application request
DBX39.6 DBB246...249
x
x
x
x
x
x
Teach-in
DBX39.7 DBB250...251
x
−
−
x
x
−
d
Data are accepted, then processed in the relevant operating mode.
x Data are accepted or processed.
−
Data are rejected with error (see Error Handling, Table 11-8 column 4, No. 1).
V
Data required to move the axis.
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...