Description of Functions
9-11
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Hints to the user
Here are a few hints for starting a movement and about the response of the
FM 353 to a change of the status of the S7-300 CPU:
It is assumed that the FM 353 has been parameterized correctly.
S
First a mode must be set. The servo enable must subsequently be set in order
to prevent the axis from “running away,”.
S
Before starting a movement in any mode, the relevant data (e.g. speed levels)
must be transferred and the override must be > 0.
S
It is only possible to start the movement when the start enable is set and the
enable input is set (if parameterized).
Enable Start is set if:
−
No error occurred
−
Mode is active
−
No Stop is called
−
Drive enable is set
S
A static Stop signal prevents all movements or block processing.
S
Response of the FM 353 to transition of the S7-300 CPU from RUN to STOP
state:
−
As described for Restart (see Section 9.3.3)
−
The digital outputs are switched off
−
Interface to the user program is switched off
S
Response of the FM 353 to transition of the S7-300 CPU from STOP to RUN
state:
A cold restart of the module is executed.
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...