Starting up
7-5
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Parameterization checklist, continued
Step
OK
What to do:
Check
3
Tool offset data Tool offset data is needed only for the “Automatic” mode and is not nec-
essary for the startup described here. Generally, it is not needed until
you start up the user program on the S7-300 CPU.
4
Traversing pro-
grams
Traversing programs are needed only for the “Automatic” mode and are
not necessary for the startup described here. Generally, it is not needed
until you start up the user program on the S7-300 CPU.
5
Create SDB
1 000
When you have completed
all start-up actions
on the FM 353 and
your plant, create, save and load SDB
1 000 into the CPU/onto the
memory card of the CPU. All the parameter data (DBs) of the FM 353
are stored in SDB
1 000. This SDB allows you to replace the FM 353
module in the event of a fault, and to download the parameters without
a programming device/PC.
Note
The measurement system (MD7) must match the measurement system specified
in the other DBs.
The measurement system raster (MSR) is the smallest distance unit in the active
system of measurement.
If at some point you have failed to take this precaution:
1. Delete all data blocks (which do not match the measurement system) or clear
the memory of the FM 353 completely.
2. Modify the other data blocks on the PG.
3. Reload the data blocks to the FM 353.
Initial contents of MD
The table below shows you what initial contents are recommended or required for
the E machine data at startup of the machine axis.
Enter the machine data in the tab windows or in table format in accordance with
the following table.
Table 7-3
Initial contents of machine data
MD (E)
Value
Explanation
5
0
FM 353 triggers no process interrupts
16
−
10
9
...+10
9
[MSR]
Specified reference-point coordinates
21/22
−
10
9
/+10
9
[MSR]
Software limit switches inactive
27
0
Reference-point shift (incremental encoders only) should be
entered for numerical readjustment of the reference point
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...