Troubleshooting
11-11
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Diagnostic interrupt, continued
Message/
Display
Error message,
error analysis and remedy
Byte.
Bit
0.2, 0.3 External channel errors Error response: “Everything Off”, as in Table 11-2
8.2
(8092)
Zero marker missing
SF
(8092)
Cause
In “reference point approach” operating mode, no zero marker was
detected within one motor revolution after the reference point switch
was passed.
SF
DC5V
DIAG
Effect
Elimination Check connection.
8.7
(8097)
For operating errors, see Table 11-5
Note:
(xxxx) value = Hexadecimal notation in diagnostic buffer
Table 11-5
Operating errors
Cl.
No.
Error message,
error analysis and remedy
Mes-
sage/
Dis-
play
Operating errors
Error response: “Everything Off”, as in Table 11-2
1 (01) 1 (01)
Software limit switch, beginning is passed
Diag-
ti
Cause
Limit switch passed: in “Control” operating mode
nostic
inter-
Effect
S
The limit switch position is passed by the necessary stop-
ping distance.
S
Set actual value is not executed.
inter-
rupt
Elimination
S
Following acknowledgment of the error, it is possible to
traverse to the working range.
S
Alter value of software limit switch (MD21)
S
Switch off monitoring limit switch occasionally!
(With the limit switches (MD21/22) disabled, the
travel range limits are established by the
maximum allowable values for the limit switches).
!
Cl. = Detail event class, No. = Detail event number
Note:
Value (xx) = Hexadecimal notation of the error number
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...