Description of Functions
9-59
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
9.4
System of measurement
Overview
At the start of parameterization, you must fill in the basic machine data item
sys-
tem of measurement
(MD7). This item governs the input of values.
Variants of the system of measurement
You can set the system of measurement for the following three units:
S
mm
S
inches
S
degrees
Input of machine data
All value inputs and all value ranges refer to the setting in the system of measure-
ment.
Internal processing of values
In “Parameterize FM 353” and in the FM 353 itself, values are processed in the
following base units:
S
0.001 mm
S
0.0001 inch
S
0.0001 degree
Examples
The sample values in the table below illustrate the relation between the system of
measurement and internal values:
System of
measurement
Internal values
Input at interface
mm
10
−
3
mm
10 995
10
−
3
mm
10.995 mm
inches
10
−
4
in(ch)
10 995
10
−
4
in(ch)
1.0995 in(ch)
degrees
10
−
4
degree
10
−
2
degree
3,600,000
10
−
4
degree
36,000
10
−
2
degree
360.0000 degree
360.00 degree
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...