Programming the Technological Functions
6-56
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
User data block (AW-DB), continued
AW-DB
FM 353
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Byte
DBB450
to
DBB469
Array, structure/data type according to data, to be read as per bytes 1 to 4 of this structure
(e.g. a program record or max. 5 MD items)
DBB470
to
DBB485
Reserved
Measured values
Measured values as per POS_MSRM call
DBD486
Initial value or in-process measured value (data type DINT)
DBD490
Final value (data type DINT)
DBD494
Measured length value
Array for operator control/monitoring
Operator control and monitoring
DBB498
Frequency
levels
transferred
Speed
levels
transferred
Increm.
dim. trans-
ferred
Teach-in
transferred
Prog. sel.
transferred
MDI block
transferred Read MD
Write MD
DBB499
Operator/
traversing
error
Data error
Diagnostic
interrupt
Zero offset
transferred
Set actual
value
transferred
MDI block
transferred
on-the-fly
DBW500
MD number
DBD502
MD value (data type DINT)
DBB506
Incremental dimension number
DBB507
Reserved
DBW508
Display number
DBW510
Keyboard code
DBW512
Reserved
Operating mode selection
DBB514
Jog mode
Auto mode Auto/single
block mode
MDI
Incremen-
tal mode
(relative)
Approach
to refer-
ence point
Open-loop
control
mode
DBB515
Acknowl-
edge
diagnostic
interrupt
Acknowl-
edge error
Note
For the symbolic signal designations, please refer to the “FMSTSV_L” library, UDT
1 block, or to the “FM353_354” library, DB 1 (IFFM_CTRL).
Содержание SIMATIC FM 353
Страница 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 26: ...Basic Principles of Positioning 2 4 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 148: ...Programming the Technological Functions 6 68 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Страница 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...