Controller
6.6 Connecting terminals and interfaces
ATE500E
System Manual, 09/2017, A5E33917696-AD
65
6.6.3
Voltage output
Note
The 24 V output (X4) is a control voltage for supplying the control inputs.
Use shielded cables (shield to be applied by the customer) if the output in the elevator
system is used as a supply output in accordance with EN 12015 as described in Section 6.3
and the cable is longer than 2 m.
Slot X4
Function
DC OUTPUT
24 V ±10 %, max. 400 mA
See also
Digital input signals (Page 62)