Controller
6.2 Drive functions
ATE500E
System Manual, 09/2017, A5E33917696-AD
29
6.2.8
Overload protection
Description of function
If the drive motor or controller are subject to high loads, an automatic overload protection
function will activate, based on the temperature of the motor or controller.
The overload protection initially reduces the drive parameters. If a specific maximum
temperature is exceeded, the motor is deenergized when at a stop, and executes no further
drive commands until the temperature has fallen.
"4" is shown on the 7-segment display (H401) while the overload protection is active.
Table 6- 1
Temperature ranges of overload protection
Temperature ranges
[in °C]
Overload protection response
Motor
Controller
95 … 100
91 … 95
Reduction of the acceleration and braking ramps to a minimum of
300 mm/s².
83 … 100
80 … 95
Reduction of the maximum speed to a minimum of 150 mm/s.
95 … 100
91 … 95
Increase of the hold-open time to between 2 and 10 seconds.
83 … 100
80 … 95
Increase of the idle time în the event of oscillation in the end position
between 10 and 30 seconds.
> 100
> 95
When stopped, the motor is deenergized.
< 95
< 91
If the motor has been deenergized because of a temperature rise,
the deenergized state is exited again.
6.2.9
Vandalism protection/continuous door monitoring
Description of function
The vandalism protection/continuous door monitoring function offers protection against
unwanted external system motion. If the motor is deenergized, the motor speed is monitored
by the controller.
If a speed of 250 mm/s is exceeded, the door is braked. The brake is deactivated when the
door speed falls below 50 mm/s.
Содержание SIDOOR ATE500E
Страница 1: ......
Страница 53: ...Controller 6 4 Operation and parameter assignment ATE500E System Manual 09 2017 A5E33917696 AD 53 ...
Страница 54: ...Controller 6 4 Operation and parameter assignment ATE500E 54 System Manual 09 2017 A5E33917696 AD ...
Страница 56: ...Controller 6 4 Operation and parameter assignment ATE500E 56 System Manual 09 2017 A5E33917696 AD ...
Страница 57: ...Controller 6 4 Operation and parameter assignment ATE500E System Manual 09 2017 A5E33917696 AD 57 ...
Страница 58: ...Controller 6 4 Operation and parameter assignment ATE500E 58 System Manual 09 2017 A5E33917696 AD ...
Страница 95: ...Motor 7 2 Installation ATE500E System Manual 09 2017 A5E33917696 AD 95 ...