Connection and commissioning
ATE500E
System Manual, 09/2017, A5E33917696-AD
141
Final checks
Final check of the permissible energies and forces.
WARNING
Risk of injury due to moving mechanical parts
Check permissible forces and energies after the door drive has been commissioned in the
complete system and adjust them if they exceed their limit values.
Please observe the valid applicable standards and directives for the respective application,
as well as the following guidelines:
•
The speed limit curve is the characteristic curve which defines the maximum permissible
door speed, v
max
, as a function of the total door panel weight.
–
According to EN 81, the maximum kinetic energy of the door in the closing direction
must not exceed 10 joules.
–
According to EN 81, the maximum kinetic energy of the door must not exceed
4 joules in the closing direction if the reversing device is disabled and every closing
operation must be signaled acoustically. An acoustic signal is not part of the
SIDOOR system and must be provided and ensured by the operator.
•
Gearing up or down is not allowed on the toothed belt because this would change the
kinetic energies or static forces on the door. The door width would then no longer be
valid.
WARNING
Risk of injury and material damage due to excessive closing or opening force of the door
Exceeding the maximum static closing and opening forces may lead to injuries to persons
or damage to the door drive and to mechanical components of the door.
Taking the counterweights into account, the maximum static closing and opening forces
must not exceed 150 N!
Содержание SIDOOR ATE500E
Страница 1: ......
Страница 53: ...Controller 6 4 Operation and parameter assignment ATE500E System Manual 09 2017 A5E33917696 AD 53 ...
Страница 54: ...Controller 6 4 Operation and parameter assignment ATE500E 54 System Manual 09 2017 A5E33917696 AD ...
Страница 56: ...Controller 6 4 Operation and parameter assignment ATE500E 56 System Manual 09 2017 A5E33917696 AD ...
Страница 57: ...Controller 6 4 Operation and parameter assignment ATE500E System Manual 09 2017 A5E33917696 AD 57 ...
Страница 58: ...Controller 6 4 Operation and parameter assignment ATE500E 58 System Manual 09 2017 A5E33917696 AD ...
Страница 95: ...Motor 7 2 Installation ATE500E System Manual 09 2017 A5E33917696 AD 95 ...