Appendices
A.2 Profiles and adjustment ranges
ATD4xxW Door Controller for Industrial Applications
302
System Manual, 01/2017, A5E38080677-AB
Parameter
Parameter ID
Unit
Profile 1*
Adjustment range
ATD4xxW
Reversal ramp open/close
p3675
mm/s
2
1200
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Acceleration ramp close
p3676
mm/s
2
500
300 ... 1400
As of (V1.09): 250 ...
1400
Deceleration ramp close
p3677
mm/s
2
500
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Reversal ramp close/open
p3678
mm/s
2
850
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Idle torque open
p3679
A
1
0 … 2.5
Idle torque close
p3680
A
1
0 … 2.5
Peak torque close
p3681
A
3
0 … 5
Static force limit open
p3682
N
75
70 … 360
Static force limit close
p3683
N
75
70 … 360
Limit force end close
p3684
N
75
70 … 360
Static NDG-force (reduced)
p3685
N
75
70 … 360
Limit energy close
p1202
J
4
0 … 100
Limit energy open
p1203
J
4
0 … 100
Limit energy NDG
p1204
J
4
0 … 100
* Default profile (this profile is automatically loaded at the first commissioning)
A.2.5
SIDOOR MDG400 L / R
SIDOOR ATD4xxW
See Table A-43 Parameters and adjustment range SIDOOR M4 L / R apply for the SIDOOR
ATD4xxW controller (Page 301).
SIDOOR ATD4xxW
See Table A-43 Parameters and adjustment range SIDOOR M4 L / R apply for the SIDOOR
ATD4xxW controller (Page 301), SIDOOR ATD4xxW column.