SIDOOR Service Tool
7.3 Operation
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
245
Operating principle
Action
Key
Remarks
1
Select required parameter
2
Activate parameter for setting
using the Return key
Parameter value flashes
3
Increase or decrease parameter
value
4
Accept parameter value by press-
ing Return key again
Displayed parameter value stops flashing
after acceptance.
5
•
Select the next parameter
(Step 1)
or
-
•
exit the menu
Note
Parameter changes are accepted with the door at a complete stop or in the OPEN or
CLOSED position.
WARNING
Risk of injury due to moving mechanical parts
After parameters have been changed, the permitted energies and forces have to be
checked by service staff and adjusted if they exceed their limit values. This has to be done
on the heaviest door in the entire system with the shaft door and cabin door coupled.
Menu navigation
You can find the menu navigation for the SIDOOR Service Tool in the section Navigation