Connecting and commissioning
9.3 Connecting a geared motor to the control unit
ATD4xxW Door Controller for Industrial Applications
264
System Manual, 01/2017, A5E38080677-AB
9.3
Connecting a geared motor to the control unit
Connecting a geared motor to the control unit
1.
Connect the motor connector with slot X7 on the SIDOOR ATD4xxW control unit
Note
The X6 control inputs plug is not plugged in during commissioning in order to prevent
uncontrolled movements.
2.
Plug the motor cable connector into the SIDOOR MDG400 L/R or MDG400NMS L/R
geared motor.
–
①
Remove the protective cover from the connection plug of the motor.
–
②
Plug the round connector of the cable (6FB1104-0AT..-0CB.) into the motor plug
socket (6FB1103-0AT1.-.M.0). Ensure that the round connector is in the correct
position. Turn the round connector so that the outer code rings match the code rings
on the plug socket.