Connecting up, switching on
4.2 Line, motor and DC link connection
Power Module PM330
Hardware Installation Manual, 12/2018, A5E32844552B AF
37
Line and motor terminals
Frame sizes GX, HX
The diagram shows the layout
of line and motor terminals and
terminal strip X9.
Optionally, the line connection
can be established using the
"Installation set for line-side
cable connection, left", see
Chapter "Installation set for line-
(Page 43)".
Tightening torques for the line,
motor and PE terminals (M12):
50 Nm
The cable entry protection (
①
)
must be broken out correspond-
ing to the diameter of the cable
to be introduced.
After connecting, the covers of
the line and motor terminals
must be reinstalled (tightening
torque: 6 Nm).
Содержание PM330
Страница 1: ......
Страница 2: ......
Страница 8: ...Table of contents Power Module PM330 6 Hardware Installation Manual 12 2018 A5E32844552B AF ...
Страница 20: ...Introduction Power Module PM330 18 Hardware Installation Manual 12 2018 A5E32844552B AF ...
Страница 146: ...Appendix A 6 Abbreviations Power Module PM330 144 Hardware Installation Manual 12 2018 A5E32844552B AF ...
Страница 149: ......
Страница 150: ......