Service Manual
6-273
Configuring the system specifically for the client
Comments about the system’s programming codes
S
0
line operation mode (190)
This setting specifies the type of connection, either Point-to-Point, Point-to-Multipoint, or S
0
Bus) between the S
0
module and
the local carrier’s lines.
Symmetric/Asymmetric Call (074)
This setting configures the system for symmetric or asymmetric calls.
Check with your local carrier to find out which operating mode should be configured for your system.
No ACK Setup for S
0
line (075)
Check with your local carrier to find out which operating mode should be configured for your system.
Notify (076)
Check with your local carrier to find out which operating mode should be configured for your system.
Automatic Keypad (077)
Your local carrier can inform you which ISDN features can be controlled by code in your country.
This feature allows you to activate the appropriate ISDN function at the terminal, without the need for external access.
Assignment of a digital line to an MSN (078)
This features allows you to assign the MSNs provided by your local carrier to calls made over digital lines.
External line prefix (189)
This setting specifies the prefix for the PABX external lines, for domestic and international calls. By default, the type of a pro-
grammed called is not specified.
External number registration (191)
To use the attendant feature, each external number must be registered to a specific slot.
If the prefix (Code 089) for these numbers has already been configured, only the final digits need to be registered.
By default, no digits are specified.
Assigning MSNs to attendants (192)
MSNs registered for each slot (see MSN Extension Assignment for Outgoing External Calls (086)) must be assigned to exten-
sions, call groups or a mailbox using a virtual EVM port (see Mailboxes assignments (203)) designated for answering calls dur-
ing a specified period of time.
An extension. Group or EVM virtual port cannot be assigned more than once. A distinctive tone on the handset indicates an
invalid entry.
With the HiPath 1120, the
S
0
module’s first port can only be a trunk, PP or PMP. It
cannot be programmed as an
S
0
bus.
With other switches, the first port may also be configured as an
S
0
Bus.
Содержание HiPath 1100
Страница 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Страница 14: ...Figures 14 Service Manual ...
Страница 124: ...Modules 3 124 Service Manual Interconnect cables ...
Страница 162: ...Installation 4 162 Service Manual Installing modules Figure 4 31 Installing a Music module HiPath 1120 ...
Страница 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Страница 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Страница 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Страница 384: ...Abbreviations 9 384 Service Manual ...
Страница 388: ...388 Service Manual ...