Modules
3-76
Service Manual
Expansion modules (EB)
7-segment display readings (H801) (S2 access)
Display
Reading
Meaning
0
Continuous
Wait connection with S2M Maintenance tool.
1
Continuous
Starting TME1 module.
E
Continuous
Waits 10 seconds for a command from the software (S2M
Maintenance).
8
Continuous
Transferring memory contents to DRAM memory.
Continuous
Checking and validating contents of Flash memory.
A
Continuous with
segment “g”
blinking
TME1 module active with both links established.
2
or
3
Continuous
Loading software from Flash.
7
Continuous
Writing software to Flash memory.
F
Continuous
Checking transferred data.
3
Cycle - Live
Clearing Flash memory.
f e
Alternating
Flash memory cleared.
h
Continuous
No software in Flash memory. Waiting for Tool to download
software
8.
Continuous
Power up reset.
Continuous
Clearing Flash memory.
Continuous
DIU-S2M starting.
blinking
DIU-S2M operating normally. If it stops blinking, indicates
that the module is no longer working.
.
blinking
TME1 is synchronizing clock via external network.
Содержание HiPath 1100
Страница 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Страница 14: ...Figures 14 Service Manual ...
Страница 124: ...Modules 3 124 Service Manual Interconnect cables ...
Страница 162: ...Installation 4 162 Service Manual Installing modules Figure 4 31 Installing a Music module HiPath 1120 ...
Страница 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Страница 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Страница 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Страница 384: ...Abbreviations 9 384 Service Manual ...
Страница 388: ...388 Service Manual ...