System Data
System expansion limitations
Table 2-1
Specific limitations to system expansion
Extension ( digital)
23
89
143
System Telephones (KS + optiPoint)
(see “CTR-UP0/E module” on page 3-79)
2KS
+
8 optiPoint
(4 4
slave)
or
4KS
8 KS
+
16 optiPoint
(8 8
slave)
8 KS
+
16 optiPoint
(8 8
slave)
or
24 KS (CD 16
module)
Digital line with TME1/Digital line with S
0
0/2
30/10
45/20
External analog lines without TME1 or S
0
modules
6
16
40
Digital line (TME1) + analog line/digital line
(S0)+ analog line
0/8
32/16
45/44
*
Each system telephone (KS) that is connected occupies one analog telephone slot.
**
S
0
and TME1 modules cannot be used simultaneously.
LAN and TME1 interface modules can be used simultaneously in HiPath 1150/1190.
- HiPath 1120 : ADSL modules, SLIMC and SADSLIM module
- HiPath 1150/1190 :ADSL modules, SLIMC and SADSLIM module
*** When the maximum capacity for external lines is exceeded due to the installation of EB, S
0
or TME1 modules, the system
disables external analog lines. Extension slots, however, continue to operate as usual.
Example 1: HiPath 1150
- slot 0, MB 210,
- slot 1, EB 210,
- slot 3 TME1 - 30 digital lines
EB 210 external lines will not work, but extensions will. Since the system allows for a maximum number of 32 lines, we
cannot have any additional analog line.
Example 2: HiPath 1150
- slot 0, MB 210
- slot 3 TME1 = 30 digital lines
In this case, there are 32 external lines at most available on the system. This means there is no room for an additional EB
module with an external analog line.
30 CAS/S2 digital lines + 2 MB external analog lines = 32 external lines.
If an EB 200 was installed in slot 1 or slot 2 the module would not be operable, since it would exceed the system’s
maximum capacity for external lines.
Example 3: HiPath 1150
- slot 0, MB 210
- slot 3 TME1 = 10 digital lines
(
WARNING:
Deactivate digital line for the TME1 module and program unused digital lines on the switch as unavailable
(turn the switch off then on).
Overall, there are 12 external lines on the system. This means there are 4 additional external lines available before
reaching the maximum capacity of 16 external lines.
An additional EB 400 could be used in slot 1 or slot 2.
If an EB 800 were installed on the switch, the entire module would be inoperable since it would exceed the system’s
maximum capacity for external lines.
Содержание HiPath 1100
Страница 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Страница 14: ...Figures 14 Service Manual ...
Страница 124: ...Modules 3 124 Service Manual Interconnect cables ...
Страница 162: ...Installation 4 162 Service Manual Installing modules Figure 4 31 Installing a Music module HiPath 1120 ...
Страница 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Страница 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Страница 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Страница 384: ...Abbreviations 9 384 Service Manual ...
Страница 388: ...388 Service Manual ...