For 2-wire analog telephone sets (A, B) a momentary short-circuit should not cause any
problem.
The maximum distance for installing a KS-type system telephone using a two-pair cable with a
0.4 mm
2
copper wire is 0.3 miles and for standard telephones it is 1.5 miles.
4.18
optiPoint Master/Slave telephone HiPath 1120 connections
Figure 4-47
optiPoint Master/Slave telephone HiPath 1120 connections
Warning
KS-type system telephones are powered through the C and D wires. Take the nec-
essary precautions to avoid short circuits at the interconnect block. If a short circuit
occurs between wires C and D, the interface’s protection will take the extension out
of service. To activate the extension again, remove the short, disconnect the system
telephone then reconnect it. The interface should then start operating normally.
Important
When there are more than 4 optiPoint 500 (Master or Slave) telephones on the Hi-
Path 1120 system, an additional power supply must be used. (see Chapter 3, “List
of modules”).
!
!
Содержание HiPath 1100
Страница 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Страница 14: ...Figures 14 Service Manual ...
Страница 124: ...Modules 3 124 Service Manual Interconnect cables ...
Страница 162: ...Installation 4 162 Service Manual Installing modules Figure 4 31 Installing a Music module HiPath 1120 ...
Страница 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Страница 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Страница 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Страница 384: ...Abbreviations 9 384 Service Manual ...
Страница 388: ...388 Service Manual ...