5.2.4.4
Connecting the Modbus (CH1)
1. Remove cap and ferrule from cable gland and slide onto cable.
2. Push cable through open gland and cable path.
3. Restore ferrule and tighten cap to lightly hold cable in place.
4. Signal cable screen is folded back over outer sheath and grounded beneath cable clamp.
5. Connect wires to terminals using wiring tool, field mount transmitter
5
4
6
7
Modbus
④
In + (B)
⑤
In - (A)
⑥
Out + (B)
⑦
Out - (A)
Functional Earth
6. Connect wires to terminals using wiring tool, wall mount transmitter.
Modbus
④
In + (B)
⑤
In - (A)
⑥
Out + (B)
⑦
Out - (A)
7. Tighten cable gland.