6.5.3
Removal/Shifting of the Master Module
To remove CP-802x again or to change its position on the DIN rail, the locking hooks must be
opened again.
Insert a screwdriver suitable for
slotted screws into the locking
hook (as shown in the picture).
The screw driver must have con-
tact to the housing. The locking
hooks are opened by carefully
pushing the screwdriver down-
wards
j
resp. upwards
k
.
When the locking hooks are
locked on the housing you can
pull the module off forward.
Note
If external I/O Modules are coupled to your device, then you can only remove the device after separating
the external I/O Modules.