System Components and Technical Data
144
Unrestricted
SICAM A8000 / CP-8000 • CP-8021 • CP-8022 Manual
DC8-037-2.02, Edition 10.2017
5.7.1.1.2 Technical Data
Binary inputs
12 binary inputs
•
2 groups (with 8 and with 4 inputs)
•
Via optocouplers the inputs are galvanical insulated from logi-
cal circuits and ground with double insulation.
•
Each group is galvanically insulated from the other group,
from logical circuits and from ground with double insulation
•
For each group one common return with selectable polarity
•
Function and status of the inputs via display
Filter time
1 dedicated input per group
2 ms
All other inputs
3 ms
Nominal voltages
24/48/60 VDC
Operating points
Logical 0
≤
12 V
Logical 1
≥
18 V
Dynamic suppression of noise
caused by cable capacitance
typ. 220 nF (for 18…78 VDC)
Rated current
0.6…1.5 mA (at 18…78 V)
Input circuits
18…78 VDC (operated by means of an external voltage)
Rated impulse voltage
4 kV
Connectors
Terminals
Removable screw terminals (grid size 5.08)
Содержание CP-8000
Страница 10: ...Open Source Software 10 Unrestricted SICAM A8000 CP 8000 CP 8021 CP 8022 Manual DC8 037 2 02 Edition 10 2017 ...
Страница 74: ...Function Packages 74 Unrestricted SICAM A8000 CP 8000 CP 8021 CP 8022 Manual DC8 037 2 02 Edition 10 2017 ...
Страница 468: ...Engineering via SICAM WEB 468 Unrestricted SICAM A8000 CP 8000 CP 8021 CP 8022 Manual DC8 037 2 02 Edition 10 2017 ...
Страница 524: ...Service 524 Unrestricted SICAM A8000 CP 8000 CP 8021 CP 8022 Manual DC8 037 2 02 Edition 10 2017 ...
Страница 556: ...Error Handling 556 Unrestricted SICAM A8000 CP 8000 CP 8021 CP 8022 Manual DC8 037 2 02 Edition 10 2017 ...
Страница 603: ...Use Cases SICAM A8000 CP 8000 CP 8021 CP 8022 Manual Unrestricted 603 DC8 037 2 02 Edition 10 2017 ...
Страница 604: ......