![Siemens ASIC SIM 1-2 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/siemens/asic-sim-1-2/asic-sim-1-2_function-manual_377074028.webp)
Functional Description of the SIM 1-2
SIM 1-2
28
C79000-G8976-C215-01
2.5 Internal
Functions
2.5.1 Impedance
Converter
The impedance converter/current modulator and current control function units
together along with a few external components and the internal shunt regulator
form the high-impedance decoupling of the auxiliary power from the bus cable.
2.5.2 Shunt
Regulator
The shunt regulator derives a stabilized voltage VE from the constant current. The
part of the total current not required by external loads is diverted to GND. The load
current can be taken in any proportions from the power supplies VREG and the
DC/DC converter (external transformer necessary).
2.5.3 Signal
Filter
The combined input high pass, band pass and low pass filter suppresses
disturbances outside of the signal transmission range from 7 kHz to 40 kHz. The
band pass and low pass filter is implemented as a switched capacity filter. The
input high pass filter is made up of R
EX1
and C
RXIN .
Содержание ASIC SIM 1-2
Страница 6: ...Preface SIM 1 2 6 C79000 G8976 C215 01 ...
Страница 41: ...Technical Specifications SIM 1 2 C79000 G8976 C215 01 41 3 3 Housing MLPQ 40 Drawing of the Housing ...
Страница 44: ...Technical Specifications SIM 1 2 44 C79000 G8976 C215 01 ...
Страница 46: ...Application Examples SIM 1 2 46 C79000 G8976 C215 01 ...
Страница 50: ...Application Examples SIM 1 2 50 C79000 G8976 C215 01 Signal Evaluation in the Demodulator ...
Страница 58: ...Application Examples SIM 1 2 58 C79000 G8976 C215 01 ...