Functional Description of the SIM 1-2
SIM 1-2
C79000-G8976-C215-01
17
2.3
Basic Functions of the SIM 1-2
The basic functions described in this section are required for the minimum
functionality of the SIM 1-2.
2.3.1 Interfacing
with
the
Bus Cable: VBUS and GND
The interfacing to the positive side of the bus system is over VBUS. Externally, at
least one diode must be included as polarity reversal protection to avoid both
destruction of the ASIC and return feed to the bus cable if a short-circuit occurs.
The interfacing to the negative side of the bus system is over GND.
As an alternative to a diode as polarity reversal protection, a rectifier bridge can be
used as polarity reversal protection and feedback protection.
2.3.2 Control Loop: CTR
This output controls the base of the external PNP transistor T1 that supplies the
local consumer connected to VE and switches to output signal to the bus by
modulating the current consumption.
2.3.3 Current Sensing by SENSEP and SENSEM
The shunt resistor R
SENSEP
is used to sense the current available as supply current
over the collector. The current fed past R
SENSEP
over VBUS and CRT is sensed by
the shunt resistor R
SENSEM
.
The sum of the two currents corresponds to the current taken from the bus.
Содержание ASIC SIM 1-2
Страница 6: ...Preface SIM 1 2 6 C79000 G8976 C215 01 ...
Страница 41: ...Technical Specifications SIM 1 2 C79000 G8976 C215 01 41 3 3 Housing MLPQ 40 Drawing of the Housing ...
Страница 44: ...Technical Specifications SIM 1 2 44 C79000 G8976 C215 01 ...
Страница 46: ...Application Examples SIM 1 2 46 C79000 G8976 C215 01 ...
Страница 50: ...Application Examples SIM 1 2 50 C79000 G8976 C215 01 Signal Evaluation in the Demodulator ...
Страница 58: ...Application Examples SIM 1 2 58 C79000 G8976 C215 01 ...