Power Supply of the Application
For the power supply of the external application electronics, it is only ever possible
to take as much energy as is taken on average from the bus system less the power
consumption of the SIM 1-2 itself.
2.4.1 Power Supply VREG
The V
REG
voltage that can be set between 2 V and 5 V regulated by R
RVREG
is
available as a non-floating power supply for the external application electronics.
The V
REG
power supply can be subjected to a maximum load of 50
mA
.
R
RVREG
[M
Ω
] = 0.5 * VREG [V]
Conditions for R
VREG
: 1 M
Ω
<= R
VREG
≤
2.5 M
Ω
Notice:
You achieve the minimum VREG tolerance of 3 % if you use a resistor with a
tolerance of
≤
0,1 % for R
RVREG
(see also the tolerance calculation in section
2.3.7, "Reference Circuit RIREF, RVCCVE, RVREG, RISOLL“).