Functional Description of the SIM 1-2
SIM 1-2
C79000-G8976-C215-01
25
2.4.2 Power Supply VE
Caution
The VE voltage of 6.3 V generated by the shunt regulator cannot be used
immediately after turning on the power supply of the external application
electronics since this can disrupt the startup of the SIM 1-2 considerably.
On completion of the startup phase (indicated by RESETXN), the VE voltage can
be used to supply the external application electronics. It is, however, important to
make sure that the VE never falls below 80% as a result of sudden load changes.
If the VE voltage sinks below 90% of VE
SOLL
, a prewarning PDWNXN (low-active)
is output (PDWNXN changes to logic '0' for 10 µs). Communication over TxE, TxS,
RxA and RxS is not affected by this.
If the VE voltage falls below 80% of VE
SOLL
, the DC/DC converter and the VREG
regulator are turned off. They start again only when VE has reached 92 % again.
When using C
VE
backup capacitors higher than 33 µF, it is advisable to connect a 1
Ω
resistor in series with the capacitor C
VE
to minimize the risk of superimposing
oscillations on the VE power supply.
Содержание ASIC SIM 1-2
Страница 6: ...Preface SIM 1 2 6 C79000 G8976 C215 01 ...
Страница 41: ...Technical Specifications SIM 1 2 C79000 G8976 C215 01 41 3 3 Housing MLPQ 40 Drawing of the Housing ...
Страница 44: ...Technical Specifications SIM 1 2 44 C79000 G8976 C215 01 ...
Страница 46: ...Application Examples SIM 1 2 46 C79000 G8976 C215 01 ...
Страница 50: ...Application Examples SIM 1 2 50 C79000 G8976 C215 01 Signal Evaluation in the Demodulator ...
Страница 58: ...Application Examples SIM 1 2 58 C79000 G8976 C215 01 ...