List of abbreviations
C.1 Table of abbreviations
3VA molded case circuit breakers
510
Manual, 04/2015, A5E03603177010-02
Abbreviation
Meaning
I
Instantaneous (short-circuit protection)
I
Isolated
I- / O-
Input / Output
IEC
International Electrotechnical Commission
INST [tripping char-
acteristic]
INST [tripping characteristic]
INSTA
Final distribution area
IP
International Protection
IT
Injection Tester
IT
Isolated ground, French: "Isolé Terre"
L
Long-time delay (overload protection)
L
Overload protection
LBS
Load Break Switch (switch disconnector)
LCS
Leading changeover switch
LI
Overload protection (L) and instantaneous short-circuit protection (I)
LIG
Overload protection (L), instantaneous short-circuit protection (I) and ground-
fault protection (G)
LIN
Overload protection (L), instantaneous short-circuit protection (I) and neutral-
conductor protection (N)
LSI
Overload protection (L), short-time delayed short-circuit protection (S) and
instantaneous short-circuit protection (I)
LSIN
Overload protection (L), short-time delayed short-circuit protection (S), instan-
taneous short-circuit protection (I) and neutral-conductor protection (N)
LSING
Overload protection (L), short-time delayed short-circuit protection (S), instan-
taneous short-circuit protection (I) and ground-fault protection (N)
LT [tripping charac-
teristic]
Partial overload range of the characteristic curve of a switching device
MCCB
Molded case circuit breaker
MO
Motor operator
MRCD
Modular residual current device [without integrated trip device]
N
Neutral conductor
NC
Normally closed contact
NEMA
National Electrical Manufacturers Association
NFPA
National Fire Protection Association.
NO
Normally open contact
LV
Low voltage
LV fuse
Low-voltage fuse
PAC
Power Analysis & Control
PI
Plug-in (unit)
RCD
Residual Current Device
R
RESET
RCR
Residual Current Release
REC
Reclose (automatic reset)
RJ [connector]
Registered Jack
Содержание 3VA1 100 A
Страница 1: ......
Страница 2: ......
Страница 71: ...Description 2 6 Protection system 3VA molded case circuit breakers Manual 04 2015 A5E03603177010 02 71 ...
Страница 94: ...Description 2 8 Electronic trip unit 3VA molded case circuit breakers 94 Manual 04 2015 A5E03603177010 02 ...
Страница 149: ...Accessories 4 2 Internal accessories 3VA molded case circuit breakers Manual 04 2015 A5E03603177010 02 149 ...
Страница 163: ...Accessories 4 2 Internal accessories 3VA molded case circuit breakers Manual 04 2015 A5E03603177010 02 163 ...
Страница 354: ...Accessories 4 8 Residual current devices 3VA molded case circuit breakers 354 Manual 04 2015 A5E03603177010 02 ...
Страница 392: ...Accessories 4 10 EFB300 external function box 3VA molded case circuit breakers 392 Manual 04 2015 A5E03603177010 02 ...
Страница 418: ...Accessories 4 14 DIN rail adapter 3VA molded case circuit breakers 418 Manual 04 2015 A5E03603177010 02 ...
Страница 514: ...List of abbreviations C 1 Table of abbreviations 3VA molded case circuit breakers 514 Manual 04 2015 A5E03603177010 02 ...
Страница 518: ...Conversion tables 3VA molded case circuit breakers 518 Manual 04 2015 A5E03603177010 02 ...
Страница 531: ...Index 3VA molded case circuit breakers Manual 04 2015 A5E03603177010 02 531 ...
Страница 532: ......